19 PAtC / PH

19 PAtC / PH / 80%



CONSTRUCTION DATA  
Sheath:..PE BLACK; Æ =6.7±0,1mm (19 PAtC/PH -19 PAtC/PH / 80%)  
Antimigrating:..PET; H 18; Sp=0,012  
Outer braid:.......Cu-Sn; Coverage=34% ( 19 PAtC / PH)  
Outer braid:.......Cu-Sn; Coverage=80% (19 PAtC / PH / 80%)  
Outer foil:..........Al/PET/Al; H 18mm; Coverage =100%  
Dielectric:...........PEE; Æ = 4.80 ± 0,05mm  
Inner conductor:.Cu; Æ = 1.00 ± 0,01 mm  
   
 ELECTRICAL DATA DC RESISTANCE ( at 20°C):
Characteristic Impedence:....75 ± 3 W Inner condutor=23 W /Km
Capacitance:..........................52 pF/mt Outer conductor=12.8 W /Km
Velocity ratio:........................85 %  
   
ATTENUATION ( at 20°C):[ dB/m] RETURN LOSS [dB]
47 MHz...............4.5 [30 - 310] MHz >33
100 MHz.............6.4 [310-460] MHz >30
230 MHz...........9.7 [460-585] MHz >30
300 MHz...........11 [585-860] MHz >25
400 MHz...........12.9 [860-1750] MHz >20
800 MHz...........19.5  
860 MHz...........20.1  
1000 MHz.........21.5  
1350 MHz.........25.3  
1750 MHz.........30.1  
2050 MHz.........32.5 SCREENING EFFICIENCY[dB]:
2150 MHz.........33.6 [30 - 1000]MHz >50
2400 MHz.........36